Choose the appropriate flashing size.
Step flashing metal roof brick side wall.
Metal roof flashing can be use to seal gaps between roof walls.
And 3 cap the block with membrane overlapping the first two pieces and bridging the gap between the block and the wall sheathing.
When installing metal or rubber membrane roofs use continuous flashing rather than pieces of step flashing.
Flashing joints are lapped 6 in the direction of water flow.
Install base flashing under shingles or over metal roofing material.
These kinds of houses often have a roof that butts against a wall.
Install kick out flashing at the end of a roof wall intersection to divert water away from the wall and into gutters.
Usually 8 inch flashing will work but any size will work well.
Continuous flashing against a sidewall is one way to install a roof but it s not the correct way.
I ve folded it down by one inch and that keeps water from rolling between the top of the gable trim and the end wall flashing.
The metal flashing is formed with a hook edge and cleated on 12 centers.
Sidewall flashing a sidewall is a junction between a wall and a sloped portion of a roof.
But it doesn t work that way.
The flashing extends up the wall at least 4.
The flashing extends onto the roof a minimum of 2 inches 4 inches is preferable in more severe climate areas.
A vertical cut about 2 in.
If the roof runs flat up against the brick.
It is commonly used in two story and side split houses.
Long helps it to fold onto the roof sheathing.
It may seem as if a single piece of flashing would offer more protection than many pieces of step flashing.
Install shingles over the portion of step flashing on the roof.
I then add a second piece of flexible flashing tape to cover the open corner of the metal flashing and i fold it down onto the subfascia.
I fold a piece of metal flashing for the inside corner between the subfascia and the wall.
2 fold a vertical strip into the inside corner extending it above the top of the block so that the next layer of flashing will cover it shingle style.
Once even a small section of roofing cement fails you ll have a leak.
Except where walls are brick the vertical part of the sidewall flashing should extend up behind the exterior wall covering just like with headwalls.
I ve prepared the two ends of the end wall flashing and in this particular case they re overhanging a gable trim on either side.
Metal roof flashing is a galvanized sheet metal bent at right angles with about eight to 12 inches on each side of the angle.
1 run membrane down the side of the block and onto the roof underlayment.