If you installed the system yourself you can immediately grab your wiring diagram and check each connection.
Solar panel no voltage.
Check voltage open circuit from panels.
This would be the view from the back of the pv module.
Measure the battery voltage.
Simply touch the solar panel leads with the multi meter probes matching their corresponding polarity red to red black to black.
It may be that you can never get more than 12 13v.
Zero power output no power low voltage issue.
If you have voltage and current the panels are good.
It sounds like you have wired the new panels backwards to the rest of the array.
Questioning users noted that the array may have been momentarily connected to the battery with poles reversed.
Connect the positive multi lead into the positive lead of the panel through the mc4 connectors then do the same with the negative leads.
Then short the panels out and measure current.
More times than not the problem with your solar panel system is due to faulty wiring.
Solar panels wired backwards to vs to parallel connections act like a dead short solar panels are just a bunch of giant diodes connect them in the wrong polarity the panels will simply be a large set of diodes connected backwards and take current from the.
Reconnect panels to controller and if the batteries are not charging guess what.
Open circuit voltage can vary depending on your solar panel but the readings we are usually looking for are in the range of 15 to 23v.
The numbers on the multimeter screen should be in the 10 range of the numbers on your spec sheet.
If you don t find any connections that were done improperly you can then look for loose connections corrosion or oxidation.
It s also possible that one solar panel in your pv array failed.
Some exceptions may apply based on panel type.
Connect the ve solar controller output lead to the ve battery terminal.
Voltages can be read on a pv module with the use of a voltmeter or multimeter.
Another easy way takes more time.
Solar panel produces volts but no amps.
If it is proceed.
Zero output is a common problem and in nine out of ten cases it is due to a faulty inverter or charge controller.
Hopefully it is less than the solar panel controller output voltage.
3 84 kw gridtied battery backup solar system with outback power center and 12x heliene 320 panels wss outback grid tie w battery backup system for 12 heliene 60 cell modules 17 142 92.
Testing the anderson lead off the panels not at the controller 0 volts and taking of the covers on each panel no voltage.
Measuring voltage and solar panel testing.
For the open circuit voltage test first turn your multimeter to voc.
Measure the solar panel controller output voltage try to get maximum voltage by angling the panels.